Hioki MR 8730/8731
|
|
|
Hioki LR8410-20
|
|
|
Instrument products > midi LOGGER
GL220
Specifications
GL220 main unit specifications
Item Description
Number of analog input channels 10 ch
External input/output Input *1 Trigger or Sampling input 1 ch, Logic or Pulse input 4 ch
Output *1 Alarm output 4 ch
Sampling interval 10 ms to 1 h (in 10ms to 50ms, voltage only and limited channel), External
Time scale 1 sec to 24 hour /division
Trigger function Action Start or stop capturing data by the trigger
Source Start: Off, Input signal, Alarm, External *1 , Clock, Week or Time
Stop: Off, Input signal, Alarm, External *1 , Clock, Week or Time
Combination OR or AND condition at the level of signal or edge of signal
Condition Analog: Rising, Falling, Window-in, Window-out
Pulse: Rising, Falling, Window-in, Window-out
Logic: Rising or Falling
Alarm function Detecting method Level or edge of signal
Condition Analog: Rising, Falling, Window-in, Window-out
Pulse: Rising, Falling, Window-in, Window-out
Logic: Rising, Falling
Alarm output *1 4 channels, Output type: Open collector (pull-up resistor 10 kΩ)
Pulse input function *1 Accumulating count mode Accumulating the number of pulses from the start of measurement
Range: 50, 500, 5 k, 50 k, 500 k, 5 M, 50 M, 500 M counts/F.S.
Instant count mode Counting the number of pulses per sampling interval
Range: 50, 500, 5 k, 50 k, 500 k, 5 M, 50 M, 500 M counts/F.S.
Rotation count (RPM) mode Counting the number of pulses per second and then it is converted to RPM
Range: 50 rpm, 500 rpm, 5 krpm, 50 krpm, 500 krpm, 5 Mrpm, 50 Mrpm, 500 Mrpm /F.S.
Max. input pulse rate 50 k pulses/sec or 50k counts per sampling interval, 16 bits counter is used
Calculation function Between channels Addition, Subtraction, Multiplication and Division for analog input
Statistical Select two calculations from Average, Peak, Max., Min., RMS
Search function Search for analog signal levels, values of logic or pulse or alarm point in captured data
Interface to PC USB (Full speed)
Storage device Built-in Flash memory (2 giga-bytes), USB memory device *2
Data saving function Captured data Direct saving of data into built-in Flash memory or USB memory device
Others Setting conditions, Screen copy
Ring capturing mode Function: ON/OFF, Number of capturing point: 1,000 to 2,000,000
(Size of the capture data will be limited to 1/3 of available memory)
USB memory device emulation USB Memory emulation mode (Transfer or delete the file in built-in memory)
Engineering scale function Set based on the reference point of the scaled output and input signal for each channel (Voltage measurement: four points are necessary to scale the output, Temperature measurement: two points are necessary to scale the output).
Display Size 4.3 inch TFT color LCD (WQVGA: 480 x 272 dots)
Formats Waveform + Digital, Waveform only, Calculation + Digital, Expanded digital
Operating environment 0 to 45 °C, 5 to 85 %RH
(When operating with battery pack 0 to 40 °C, charging battery 15 to 35 °C)
Power source AC adapter (100 to 240 V, 50/60 Hz), DC power (8.5 to 24 V DC, max. 26.4 V) *3 ,
Battery pack *3
Power consumption 29 VA or lower (when operating with AC adapter, displaying LCD)
External dimensions (W×D×H) approx. 194 x 117 x 42 mm
Weight approx. 520 g (Excluding AC adapter and battery pack)
*1
Logic alarm cable (B-513) option is required.
Input signal of External sampling, Logic, Pulse; Maximum voltage: 24 V, Threshold: approx. 2.5 V, Hysteresis: approx. 0.5 V.
*2
Size of the USB memory device is unlimited. Maximum file size is limited to 2GB.
*3
DC drive cable (B-514) or battery pack (B-517) option is required.
Analog input specifications
Item Description
Type of input terminal Screw terminal (M3 screw)
Input method Scans by the photo-MOS-relay, all channels isolated, balanced input
Measurement range Voltage 20, 50, 100, 200, 500 mV, 1, 2, 5, 10, 20, 50 V, and 1-5 V /F.S.
Temperature Thermocouple: K, J, E, T, R, S, B, N, and W (WRe5-26)
Humidity 0 to 100% (using humidity sensor (B-530 optional), power is supplied to only one sensor)
Filter Off, 2, 5, 10, 20, 40 (moving average in selected number)
Measurement accuracy *4 Voltage 0.1 % of F.S.
Temperature Thermocouple Measurement range Measurement Accuracy
R/S 0 °C ≤ TS ≤ 100 °C
100 °C < TS ≤ 300 °C
R: 300 °C < TS ≤ 1600 °C
S: 300 °C < TS ≤ 1760 °C ± 5.2 °C
± 3.0 °C
± (0.05 % of reading + 2.0 °C)
± (0.05 % of reading + 2.0 °C)
B 400 °C ≤ TS ≤ 600 °C
600 °C < TS ≤ 1820 °C ± 3.5 °C
± (0.05 % of reading + 2.0 °C)
K -200 °C ≤ TS ≤ -100 °C
-100 °C < TS ≤ 1370 °C ± (0.05 % of reading + 2.0 °C)
± (0.05 % of reading + 1.0 °C)
E -200 °C ≤ TS ≤ -100 °C
-100 °C < TS ≤ 800 °C ± (0.05 % of reading + 2.0 °C)
± (0.05 % of reading + 1.0 °C)
T -200 °C ≤ TS ≤ -100 °C
-100 °C < TS ≤ 400 °C ± (0.1 % of reading + 1.5 °C)
± (0.1 % of reading + 0.5 °C)
J -200 °C ≤ TS ≤ -100 °C
-100 °C < TS ≤ 100 °C
100 °C < TS ≤ 1100 °C ± 2.7 °C
± 1.7 °C
± (0.05 % of reading + 1.0 °C)
N 0 °C ≤ TS ≤ 1300 °C ± (0.1 % of reading + 1.0 °C)
W 0 °C ≤ TS ≤ 2000 °C ± (0.1 % of reading + 1.5 °C)
Reference Junction Compensation (R.J.C.): ±0.5 °C
A/D converter ΣΔ type, 16 bits (effective resolution: 1/40,000 of measuring full range)
Maximum input voltage Between + / - terminal 60 V p-p
Between channels 60 V p-p
Between channel / GND 60 V p-p
Withstand voltage Between channels 350 V p-p (1 minute)
Between channel(-)/ GND 350 V p-p (1 minute)
*4
Subject to the following conditions;
• Room Temperature is 23°C ±5°C.
• When 30 minute or more have elapsed after power was turned on.
• Filter is set to 10.
• Sampling rate is set to 1s with 10 channels.
• GND terminal is connected to the ground.
Software specifications
Item Description
Supported OS Windows XP / Vista / 7 (32 bits and 64 bits edition)
Functions Control GL220, Real-time data capture, Replay data, Data format conversion
GL220 settings control Input settings, Memory settings, Alarm settings, Trigger settings
Captured data Transfers data in real-time (in binary or CSV format), saved data in GL220 or the USB memory
Displayed information Analog waveforms, Logic waveforms, Pulse waveforms, Digital values
Display modes Y-T waveforms, Digital values, Report, X-Y graph (specified period of data, data replay only)
Warning functions Sends E-mail to the specified address when the alarm occurred
File format conversions Converts the specified period data or all data to the CSV format (thinning function is available)
Report functions Creates a daily or monthly report automatically (can also export directly to Excel)
Displayed Max. Min. Displays the maximum, minimum and current value in measurement
Standard accessories
Item Description Quantity
AC adapter 100 to 240 V AC, 50 / 60 Hz (with specified type of power cord) 1 set
CD-ROM User’s manual (PDF format), Application software 1 piece
Quick Start Guide 1 copy
|
|
|
|
|